go-e · OCPP 1.6J
Not hardware-validated by 22togo Last verified 2026-11-12go-e Charger Gemini Flex
Connect a go-e Charger Gemini Flex 22 kW three-phase charger to 22togo over OCPP 1.6J.
The go-e Charger Gemini Flex is configured via the web interface. Enable OCPP in Settings → OCPP, enter the OCPP Server (with identity path), Charge Point ID, and OCPP AuthPass (22togo token).
Before you start
- A 22togo station record with its exact identity (Charge Point ID) and OCPP auth token.
- The OCPP server URL shown in the 22togo app for that station (including identity path).
- The charger installed, powered, and connected to the local network (Wi-Fi or Ethernet).
- A computer/phone with web browser on the same network.
Settings to enter
Use these values when configuring the charger's OCPP backend.
| Setting | Value | Notes |
|---|---|---|
| OCPP Server | wss://<ocpp-host>/<identity> |
Use the exact URL from the 22togo app. Must include the identity path segment. |
| Charge Point ID | <identity> |
Must match the 22togo station identity exactly. |
| OCPP AuthPass | <ocpp_auth_token> |
Enter the per-station auth token from 22togo. go-e calls this 'OCPP AuthPass'. |
| OCPP Version | OCPP 1.6J |
Select OCPP 1.6-J. |
| Network | Wi-Fi or Ethernet |
Configure Wi-Fi (via app or hotspot) or Ethernet before OCPP. |
Setup steps
Follow the steps in order. Restart the charger after changing backend settings.
-
1
Access the go-e web interface
- Connect your device to the same network as the charger (Wi-Fi or Ethernet).
- Open a browser to
http://go-e.local(or the charger’s IP address from your router). 3. Log in with the admin password (default:go-eor on the label).
The go-e charger creates a mDNS hostname
go-e.local. If that doesn’t resolve, find the IP in your router’s DHCP list. -
2
Configure network connection
- Go to Settings → Network.
- For Wi-Fi: select your SSID, enter password, save.
- For Ethernet: DHCP is automatic; plug in cable. 4. Verify internet connectivity (green status).
The go-e app can also configure Wi-Fi during initial setup. Ethernet is recommended for stable OCPP.
-
3
Configure OCPP settings
- Go to Settings → OCPP.
- Enable OCPP.
- Set OCPP Version to OCPP 1.6-J.
- In OCPP Server, enter the full 22togo WebSocket URL including identity path (e.g.,
wss://ocpp.22togo.com/CHG-001). - In Charge Point ID, enter the exact station identity from 22togo.
- In OCPP AuthPass, enter the OCPP auth token from 22togo. 6. Click Save.
go-e uses the field name ‘OCPP AuthPass’ for the authorization token. Enter the 22togo per-station token here.
-
4
Restart and verify
- After saving, the charger will restart automatically (or click Restart).
- Log back in and check Status → OCPP — should show ‘Connected’ with OCPP 1.
-
- In 22togo app, station should show ‘Online’.
If connection fails, verify server URL (includes identity path), Charge Point ID, and OCPP AuthPass. Check the OCPP log in the web interface.
Charger capabilities
What this model supports with 22togo over OCPP.
-
OCPP 1.6J
-
Web interface commissioning
-
Wi-Fi & Ethernet
-
OCPP AuthPass support
-
Smart charging profiles
-
PV surplus charging
go-e's PV surplus feature works alongside OCPP smart charging.
Frequently asked questions
What makes Gemini Flex different?
The Flex adds a flexible cable management system and can be configured for both tethered and untethered use. OCPP setup is identical to Gemini.
Does Flex support RFID?
Yes. Includes RFID reader for local authorization alongside OCPP.
Can Flex use both Wi-Fi and Ethernet simultaneously?
Yes. The Flex supports both interfaces with automatic failover.
Sources