Keba · OCPP 1.6J
Not hardware-validated by 22togo Last verified 2026-11-12Keba KeContact P30
Connect a Keba KeContact P30 22 kW three-phase charger to 22togo over OCPP 1.6J.
The Keba KeContact P30 is configured via the web interface. Enable OCPP in Settings → OCPP, enter the OCPP Server (with identity path), Charge Point ID, and OCPP AuthPass (22togo token, sent as Basic Auth password).
Before you start
- A 22togo station record with its exact identity (Charge Point ID) and OCPP auth token.
- The OCPP server URL shown in the 22togo app for that station (including identity path).
- The charger installed, powered, and connected to the local network (Ethernet).
- A computer with web browser on the same network.
Settings to enter
Use these values when configuring the charger's OCPP backend.
| Setting | Value | Notes |
|---|---|---|
| OCPP Server | wss://<ocpp-host>/<identity> |
Use the exact URL from the 22togo app. Must include the identity path segment. |
| Charge Point ID | <identity> |
Must match the 22togo station identity exactly. |
| OCPP AuthPass | <ocpp_auth_token> |
Enter the per-station auth token from 22togo. Keba uses 'OCPP AuthPass' (HTTP Basic Auth password). |
| OCPP Version | OCPP 1.6J |
Select OCPP 1.6-J. |
| Network | Ethernet (DHCP or Static) |
Keba P30 uses wired Ethernet. Configure IPv4 before OCPP. |
Setup steps
Follow the steps in order. Restart the charger after changing backend settings.
-
1
Access the Keba web interface
- Connect your computer to the same Ethernet network as the charger.
- Open a browser to
http://kecontact.local(or the charger’s IP address from your router). 3. Log in with the admin password (default:kebaor on the label).
Keba P30 uses mDNS hostname
kecontact.local. If that doesn’t resolve, find the IP in your router’s DHCP list. Keba chargers use wired Ethernet only. -
2
Configure network settings
- Go to Settings → Network.
- Set IPv4 Configuration to DHCP (or Static IP with your network details). 3. Apply and verify the charger has internet access.
If using Static IP, ensure DNS and gateway are correct for internet access.
-
3
Configure OCPP settings
- Go to Settings → OCPP.
- Enable OCPP.
- Set OCPP Version to OCPP 1.6-J.
- In OCPP Server, enter the full 22togo WebSocket URL including identity path (e.g.,
wss://ocpp.22togo.com/CHG-001). - In Charge Point ID, enter the exact station identity from 22togo.
- In OCPP AuthPass, enter the OCPP auth token from 22togo. 6. Click Save.
Keba uses ‘OCPP AuthPass’ for the authorization token (sent as HTTP Basic Auth password). The username is the Charge Point ID.
-
4
Restart and verify
- After saving, the charger will restart automatically (or click Restart).
- Log back in and check Status → OCPP — should show ‘Connected’ with OCPP 1.
-
- In 22togo app, station should show ‘Online’.
If connection fails, verify server URL (includes identity path), Charge Point ID, and OCPP AuthPass. Check the OCPP log in the web interface.
Charger capabilities
What this model supports with 22togo over OCPP.
-
OCPP 1.6J
-
Web interface commissioning
-
Ethernet only
Wired Ethernet only; no Wi-Fi or 4G on P30.
-
OCPP AuthPass support
-
Smart charging profiles
-
Modbus/TCP for energy meters
Frequently asked questions
Does KeContact P30 support OCPP 1.6J?
Yes. The P30 supports OCPP 1.6J via the web interface (Settings → OCPP).
Does P30 have Wi-Fi?
No. The P30 uses wired Ethernet only. No Wi-Fi or 4G.
Does P30 have a MID meter?
The P30 x-series includes a MID-certified meter. The c-series does not. Check your model variant.
Sources
These steps are based on public vendor documentation.